ColorBox User Guide

Working with Charts and Metrics

Use the controls above a chart to change what you see, then interact with the plot to inspect the details. Hover over a plotted point or wavelength to read its values. On charts with a magnifying glass in the header, click it to expand the chart into the available workspace. Click it again to return to the dashboard. The expanded view gives you more room to examine closely spaced points, fine spectral peaks, and long legends.

CIE chromaticity chart

Use CIE 1931 to view chromaticity in x, y coordinates, or CIE 1976 to see the same reading in u′, v′ coordinates. Both views let you inspect where the measured light falls and compare its chromaticity with other readings.

  • Zoom and pan. Pinch on the trackpad to zoom around an area of interest, then drag to pan. Use the reset button inside the plot to return to the original view.
  • Planckian locus. Click the lightbulb inside the chart to show or hide the curve and its color-temperature labels in kelvin. The curve shows where ideal blackbody sources fall at different temperatures. Use it to see how close a near-white reading is to the curve and how several readings with similar CCT differ in tint.
  • Expand. Click the magnifying glass in the chart header for a larger view. This is useful when zooming in on several readings clustered near the same white point.

Compact CIE chromaticity chart with the CIE 1931 and CIE 1976 selectors

Expanded CIE chromaticity chart with the coordinate selectors and plot controls

Spectrum chart

Use Visible to focus on the visible region or Full range to inspect all wavelengths available for the reading, including measured UV or infrared where present. Hover over the plot to see the wavelength ruler and the values of visible traces at that wavelength. Use the chart’s expand control where available to give the plot more space.

Wide spectrum chart showing the wavelength ruler and values for the measurement and overlays

Vertical axis menu

Open the menu labeled with the current quantity, such as Spectral irradiance, to change what the vertical axis represents. Choices depend on the measurement and its units.

Option When to use it
Spectral irradiance Read the measured radiant power per unit area and wavelength. Use the original quantity when the absolute level matters.
Relative spectral distribution (% of each peak) Scale each trace to its own peak so you can compare spectral shape independently of peak level.
Relative spectral distribution (% of primary peak) Scale every trace against the primary measurement’s peak so the traces share a baseline and relative peak heights remain visible.
Spectral photon irradiance View photon delivery per unit area and wavelength when comparing light by photon count.
Photopic illuminance contribution See how much each wavelength contributes to photopic illuminance after weighting for daytime visual sensitivity.
Melanopic irradiance contribution See the wavelength-by-wavelength contribution after melanopic sensitivity weighting.
Spectral share (area = 100%) Compare how each trace distributes its total across wavelengths on an equal-area basis.
Relative spectral level (dB re peak) Use a logarithmic scale to inspect weaker features alongside strong peaks. The menu shows the display floor.

Spectrum vertical axis menu with measured, relative, photon, weighted, and logarithmic views

Overlays menu

Open Overlays to turn individual references on or off. Use the legend to identify each curve or marker. The choices vary by dashboard and measurement.

  • Photopic sensitivity shows the relative wavelength sensitivity used for photopic vision. Use it to see which parts of the spectrum contribute most to illuminance.
  • Melanopic sensitivity shows the relative melanopic weighting curve. Compare it with the photopic curve to see why two sources at the same illuminance can have different melanopic values.
  • CCO reference markers and curves add modeled reference context. The individual markers identify labeled CuA or CuB bands. Combined response, CCO oxidized, and CCO reduced show the corresponding reference curves when available. Read them as relative references alongside the measured spectrum.

Overlays menu with photopic, melanopic, and CCO references

Full-range spectrum with photopic and melanopic sensitivity overlays enabled

Metric details and multiple readings

Click a metric card that offers a band breakdown to see which wavelength bands contribute to the total. For example, the Illuminance breakdown shows each band’s Share as a percentage of the evaluated total and its Contribution in lux. This helps explain why two lights with similar totals can distribute their contribution differently.

Illuminance card opened to show wavelength-band shares and contributions in lux

Some charts display several readings at once. Add readings to the comparison with the dotted controls in the Measurements sidebar. A compatible CIE chart can show several chromaticity points, a spectrum chart can draw several traces, and a comparison chart can show grouped bars. Use the marker colors, labels, and legend to match each series to its reading. A view designed for one reading can still show only the primary measurement.

For help choosing a dashboard, see Lighting Analysis Dashboards.